| What should
I do if misting nozzles plug up?
Cleaning Nozzles - Replace or clear
obstructed or clogged nozzles.
Nozzles may be cleared by scraping
the stainless steel end with flat
surface of a knife or screwdriver.
To remove nozzle, turn in counter-clockwise
direction. Nozzles may be routinely
cleaned by soaking in solution of
LIME AWAY!" or CLR overnight. Rinse
thoroughly after soaking. Replace
nozzle by turning in clockwise direction
until snug.
Where do I place my patio mist
line system?
Place mist line around the perimeter
of the area to be cooled. This forms
a mist curtain, a cooling barrier
between the protected area and the
outside heat. The mist line should
be mounted 8' to 10' above the ground.
How much water does a misting
system actually use?
This will vary depending on the
size of the system and the number
of nozzles to be used.
You can download the "Nozzle Pump
Performance" for more information.
Do I need a filter for my system?
Our high pressure systems are with
filters.
For our low and med pressure systems
you can use our Poly-Phosphate Filters.
The unique Filters actually accomplishes
two things. First, it will filter
out any sediment from the water
supply thereby preventing it from
getting into the mist line and plugging
the nozzles. Second, the filter
contains phosphate crystals which
are designed to surround the hard
water deposits (calcium, sodium,
and magnesium) and prevent them
from adhering to the misting nozzle.
This will also help eliminate the
hard water buildup and will keep
the mist system operating at peak
performance for a longer period
of time.
Is there any maintenance required?
The only maintenance required for
a properly designed misting system
is a periodic cleaning of the nozzles
and an annual check-up for the pump.
This check-up may include adding
or changing of the oil and tightening
or replacing of fan belts (only
on the pulley driven pump models),
and changing of the filter cartridge.
Misting Fan Systems require very
little maintenance. We do recommend
some preventative care and cleaning
for the nozzles.
How many nozzle can I use with
the COOLLINE product line. ( High
Pressure )
This is depending on the size of
the pump and the size of nozzles.
For more informations, you may download
the "Nozzle Pump Performance".
How many nozzle can I use with
the MIST&COOL product line.
( Low-Med Pressure )
|
MIST&COOL!"
Outdoor Cooling Systems employ
evaporative cooling to effectively
cool and condition the environment.
Using our proprietary misting
nozzles, an ultra fine mist
is introduced into the environment
which interacts with the air
to cool, clean, humidify and
to repel flying insects. |
| Maximum
number of nozzles that can
be used
at different water pressures: |
| |
| 1/2
Professional System |
3/8"
Do-It-Yourself System |
| Water Pressure |
Max. # of Nozzles |
Water Pressure |
Max. # of Nozzles |
| 25 psi |
6 |
30 psi |
6 |
| 40 psi |
18 |
40 psi |
18 |
| 50 psi |
30 |
50 psi |
30 |
| 70 psi |
42 |
70 psi |
46 |
| 180 psi |
54 |
90 psi |
62 |
| 250 psi |
58 |
100 psi |
62 |
| |
|
120 psi |
106 |
| |
| Our
heaviest duty system is designed
to work with house pressures
and pump aided pressures up
to 250 psi. Higher pressures
produce more water volume
and an even finer mist that
evaporates more efficiently. |
This
system is designed for optional
installation flexibility and
maximum number of nozzles
at pressures up to 125 psi.
Besides normal patio applications,
this system works exceptionally
well in greenhouse applications.
*Normal house pressures range
between 35 psi and 90 psi. |
|